Shop

50kW L-Band 902-928 MHz Solid State High-Power Microwave Generator

Product Description

Industrial Microwave Products

50kW L-Band 902-928 MHz Solid State High-Power Microwave Generator

Key Features

  • Internal frequency and power control
  • Software control utilizing a Windows™ based GUI
  • Frequency sweeping capability
  • Built in Forward and Reflected power measurement
  • Distributed multi‐processor control architecture
  • WR975 Waveguide output (external circulator required)

Frequency Range

  • 902‐928 MHz
  • Frequency Step Size: 100 kHz

Operating Modes

  • Fixed, single frequency

Control System

  • Windows‐based interactive control software
  • External E‐Stop
  • Local or remote operation
  • Ethernet remote control
  • PLC‐type hardware control interface with 24VDC and 20ma current loop inputs and outputs
  • Arc detection emergency stop inputs

Microwave Power Output

  • Power set resolution input values: 1 watt
  • Power Amplifiers: Rugged LDMOS transistors
  • Comprised of Qty 22, 2.5 KW modular power blades
  • Integrated RF output timer
  • Power control accuracy: 0.1%
  • Power measurement indicators: Forward & Reflected
  • Max. mismatch: 10 dB RL/2:1 VSWR

Software Highlights

  • Point and click power and frequency setting across the band
  • Forward/Reflected power and return loss indicators
  • Best frequency selection based on load measurements
  • Variable power over frequency sweep creation tool
  • Programmable initial pulse for applications such as gas / plasma ignite

Power Supply

  • AC mains: 380 or 480 VAC three phase delta 50/60 Hz configurable
  • 50‐volt switch mode power supply
  • Line‐to‐RF‐conversion efficiency at full power: 50%
  • Air Cooled

Dimensions and Weight

  • 52” (132.08cm) H x 54” (137.16cm) D x 54” (137.16cm) W
  • Weight: 1650 lbs. (748.43kg)

Facility Requirements:

  • Input Water Flow Min: 50 GPM (189.27 LPM)
  • Input Water Temperature: 15⁰C ‐ 20⁰C
  • Input Water Pressure: 60 Max PSI (2.5 Min–4.0 Max atm)
  • Environmentally Controlled:
    - Ambient Room: 15⁰C ‐ 25⁰C
    - Relative Humidity: < 95%
    - Conditions must be non‐condensing
  • Water Hook Up: 2” OD NPT Threaded
  • Heat Load: ~150kBTU/hr @ Full Power

These are Preliminary Specification’s. The information contained herein is subject to change without notice.

Together, we can amplify your results.