50kW L-Band 902-928 MHz Solid State High-Power Microwave Generator
Product Description
Industrial Microwave Products
50kW L-Band 902-928 MHz Solid State High-Power Microwave Generator
Key Features
- Internal frequency and power control
- Software control utilizing a Windows™ based GUI
- Frequency sweeping capability
- Built in Forward and Reflected power measurement
- Distributed multi‐processor control architecture
- WR975 Waveguide output (external circulator required)
Frequency Range
- 902‐928 MHz
- Frequency Step Size: 100 kHz
Operating Modes
- Fixed, single frequency
Control System
- Windows‐based interactive control software
- External E‐Stop
- Local or remote operation
- Ethernet remote control
- PLC‐type hardware control interface with 24VDC and 20ma current loop inputs and outputs
- Arc detection emergency stop inputs
- Power set resolution input values: 1 watt
- Power Amplifiers: Rugged LDMOS transistors
- Comprised of Qty 22, 2.5 KW modular power blades
- Integrated RF output timer
- Power control accuracy: 0.1%
- Power measurement indicators: Forward & Reflected
- Max. mismatch: 10 dB RL/2:1 VSWR
Software Highlights
- Point and click power and frequency setting across the band
- Forward/Reflected power and return loss indicators
- Best frequency selection based on load measurements
- Variable power over frequency sweep creation tool
- Programmable initial pulse for applications such as gas / plasma ignite
Power Supply
- AC mains: 380 or 480 VAC three phase delta 50/60 Hz configurable
- 50‐volt switch mode power supply
- Line‐to‐RF‐conversion efficiency at full power: 50%
- Air Cooled
Dimensions and Weight
- 52” (132.08cm) H x 54” (137.16cm) D x 54” (137.16cm) W
- Weight: 1650 lbs. (748.43kg)
Facility Requirements:
- Input Water Flow Min: 50 GPM (189.27 LPM)
- Input Water Temperature: 15⁰C ‐ 20⁰C
- Input Water Pressure: 60 Max PSI (2.5 Min–4.0 Max atm)
- Environmentally Controlled:
- Ambient Room: 15⁰C ‐ 25⁰C
- Relative Humidity: < 95%
- Conditions must be non‐condensing - Water Hook Up: 2” OD NPT Threaded
- Heat Load: ~150kBTU/hr @ Full Power